Abstract: The waste heat boilers in cement plants for pure low temperature waste heat power generation were arranged dispersedly and the steam production was low. To solve those problems, Sinoma Energy Conservation Ltd. developed a new type of integrated dual-pressure reheat waste heat boiler with double intake. Because of unique designs of setting chamber, groove separator, double intake from the bottom, high-pressure superheater, low-pressure superheater and high-pressure reheater, the size of this waste heater boiler is reduced effectively and its steam production is increased, further improving the performance of the cement kiln cogeneration system.
[J]. 水泥技术, 2011, 1(1): 96-97.
WEI Lianyou, ZHU Li. The Application of the Dual-pressure Reheat Waste Heat Boiler with Double Intake and in Cement Industry Cogeneration. Cement Technology, 2011, 1(1): 96-97.