Abstract: lithium metaborate fusion method decompose technique is used in the Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES)and all-components of cement analysis. The various factors affecting spectrum intensity were examined in details.The optimum conditions for the determination is tested and discussed. The limit of the method is 0.005-0.857μg·mL-1. The recycling rate ranks from 96.2% to 104.0% and RSD is less than 4.24%. This method is accurate, quick-acquired and convenient. It is used in the determination of all-components of cement samples and has gain satisfactory results.
[J]. 水泥技术, 2005, 1(1): 90-91.
XIE Hua-lin, Wen Hai-chu, LI Tan-ping . Study on the Simultaneous Determination of all-components of cement samples by Inductively Coupled Plasma-Atomic Emission Spectrometry. Cement Technology, 2005, 1(1): 90-91.